Ver. 1.07.02 (01 Jul 2024)

Fixed:

  • Calibration zero lost after firmware update or in case of low battery condition
  • Weighings stored in alibi memory lost after firmware update or in case of low battery condition

Ver. 1.07.01 (02 Dec 2022)

Correzioni

  • Printouts: if printing of header/footer is disabled, printing is not executed
  • TMU295 printer: ticket not release after printing is concluded

Ver. 1.07.00 (04 Nov 2022)

Added

  • First firmware revision with service software Instrument Manager support
  • Printouts: customized footer available

Fixed

  • ASCII protocol: with NETEN parameter enabled, semi-automatic tare and preset tare are allowed yet

Ver. 1.06.01 (12 Aug 2022)

Internal changes without any impact on the user

Ver. 1.06.00 (25 Feb 2022)

Added

  • First firmware release NTEP certified
  • Printer: EPSON TMT20III supported

Ver. 1.05.05 (02 Oct 2019)

Fixed

  • MODBUS-RTU protocol: 100 command code executes a semi-automtaic zero and not a tare weight zero setting

Ver. 1.04.05 (17 May 2019)

Internal changes without any impact on the user

Ver. 1.04.04 (08 Feb 2018)

Changed

  • Legal for trade instrument: WEIMOD protocol available, for weight value reading via serial communication
  • Legal for trade instrument: qualified access to legally relevant parameters lost when the instrument is swithced off
  • PLUSII printer: in the line dividing two printouts, sequence '::::::' used instead of '......'
  • Zero value manual entry: the parameter value is applied only when it's modified

Fixed

  • Use with multichannel transmitters: in case of legal for trade weighing system, qualifed access to legally relevant parameter doesn't work if communiucation between indicator and transmitter is not working
  • Use with multichannel transmitters: parameters related to zero tracking function not correctly saved in the internal memory, causing the function do not correctly work

Ver. 1.04.03 (10 Jan 2017)

Added

  • Printouts: introduced number of blank lines before the input weigh printout and number of blank lines before the output weigh parameters

Changed

  • Printouts: for single weighings, parameter number of blank lines before the input weigh is used as setting
  • Printouts: for single weighings, LOADED/UNLOADED row moved to the end of the printout

Fixed

  • Multichannel transmitters management: peak weight detection function not working

Ver. 01.04.00 (23 Sep 2016)

Added

  • Parameters setting: a new parameter, NETEN, is available in CALIB menu, to enable/disable semi-automatic tare and preset tare functions

Changed

  • When a tare is active, it's automatically removed only if a weighing operation is successfully completed

Ver. 1.03.00 (15 Jul 2016)

Added

  • Multichannel transmitters management: in case of CLM8 transmitter, 16 channels mode available. It allows and indicator to commuicate with two CLM8s, to get a 16 independent channels weighing system

Fixed

  • Multichannel transmitters management: real calibration, with sample weights, not correctly executed
  • CONTIN communication protocol: data transmission halted after a semi-automatic zero execution
  • Legal for trade instrument, alibi memory: for MODBUS-RTU protocol, the specific status register bit, signalling an ongoing memory search, is not working correctly

Ver. 1.01.16 (01 Jul 2016)

Added

  • Weighings storage and printing conditions: added NONE option. Weighings storage and priniting allowed also if weight value is not changed
  • Legal for trade instrument, zero tracking: allowed range for the parameter extended to 50 e/10 (thenths of e)

Fixed

  • Legal for trade instrument, automatic zero setting at power-on: tare needed to zero the weight value is not correctly calculated. Current weight value, when startup is concluded, is not equal to 0

Ver. 1.01.14 (17 Mar 2016)

Fixed

  • Use with multichannel transmitters: tare weight zero setting is not working correctly
  • Not legal fo trade instruments: due to internal backup battery issues, tare weight zero is zeroed, assuming all the calibration is lost

Ver. 1.01.12 (19 Sep 2015)

Internal changes without any impact on the user

Ver. 1.01.11 (19 Sep 2015)

Fixed

  • Printouts: STAVQ printer not correctly managed during some tickets printing

Ver. 1.01.09 (09 Sep 2015)

Fixed

  • NOTLEG program enabled: automatic zero setting at power-on not working

Ver. 1.01.07 (01 Jul 2015)

Changed

  • MASMUL communication protocol: user can select it, only after enable ESTYES option during program selection

Ver. 1.01.04 (04 Jun 2015)

Fixed

  • Communication with multichannel transmitters: load percentages on each channel reading incorrect

Ver. 1.01.03 (07 May 2015)

Internal changes without any impact on the user

Ver. 1.01.08 (06 Aug 2012)

Fixed

  • Use with multichannel transmitters: when a semiautomatic tare is executed, the current weight value is no more updated on the indicator display
  • Preset tare database: password mechanism, to access the database, not working correctly