INNOVATION IN WEIGHING

Transmissores de peso

PROCURA ALGUM PRODUTO?

Pesquisa por subfamília
Pesquisa por modelo de produto
Mostrar filtros de pesquisa
TLB4 - DIGITAL-ANALOG WEIGHT TRANSMITTER (RS485)
DIGITAL-ANALOG WEIGHT TRANSMITTER (RS485)
4 independent reading channels for load cells (individual load cell monitoring, total weight displaying, digital equalization).  

  • 16-bit Analog output: 0/4-20 mA; 0-5/10 V; ±5/10 V
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for front/back panel
TLB4 RS485 - DIGITAL WEIGHT TRANSMITTER (RS485)
DIGITAL WEIGHT TRANSMITTER (RS485)
4 independent reading channels for load cells (individual load cell monitoring, total weight displaying, digital equalization).  

  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for front/back panel
TLB4 CANOPEN - DIGITAL WEIGHT TRANSMITTER (RS485 -  CANopen)
DIGITAL WEIGHT TRANSMITTER (RS485 - CANopen)
4 independent reading channels for load cells (individual load cell monitoring, total weight displaying, digital equalization).  

  • CANopen port
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for front/back panel
TLB4 DEVICENET - DIGITAL WEIGHT TRANSMITTER (RS485 -  DeviceNet)
DIGITAL WEIGHT TRANSMITTER (RS485 - DeviceNet)
4 independent reading channels for load cells (individual load cell monitoring, total weight displaying, digital equalization).
 
  • DeviceNet port
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for front/back panel
TLB4 CC-LINK - DIGITAL WEIGHT TRANSMITTER (RS485 - CC-Link)
DIGITAL WEIGHT TRANSMITTER (RS485 - CC-Link)
4 independent reading channels for load cells (individual load cell monitoring, total weight displaying, digital equalization).

  • CC-Link port
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for front/back panel
TLB4 PROFIBUS - DIGITAL WEIGHT TRANSMITTER (RS485 -  PROFIBUS)
DIGITAL WEIGHT TRANSMITTER (RS485 - PROFIBUS)
4 independent reading channels for load cells (individual load cell monitoring, total weight displaying, digital equalization).  

  • PROFIBUS DP port
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for back panel
TLB4 PROFINET IO - DIGITAL WEIGHT TRANSMITTER (RS485 - PROFINET IO)
DIGITAL WEIGHT TRANSMITTER (RS485 - PROFINET IO)
4 independent reading channels for load cells (individual load cell monitoring, total weight displaying, digital equalization).  

  • Two PROFINET IO ports
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for front/back panel
TLB4 ETHERNET/IP - DIGITAL WEIGHT TRANSMITTER (RS485 - Ethernet/IP)
DIGITAL WEIGHT TRANSMITTER (RS485 - Ethernet/IP)
4 independent reading channels for load cells (individual load cell monitoring, total weight displaying, digital equalization).  

  • Two Ethernet /IP ports
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for front/back panel
TLB4 MODBUS/TCP - DIGITAL WEIGHT TRANSMITTER (RS485 - Modbus/TCP)
DIGITAL WEIGHT TRANSMITTER (RS485 - Modbus/TCP)
4 independent reading channels for load cells (individual load cell monitoring, total weight displaying, digital equalization).  

  • Modbus/TCP port
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • Back panel mounting on Omega/DIN rail
  • Mounting on Omega/DIN rail for front/back panel
TLB4 ETHERNET TCP/IP - DIGITAL WEIGHT TRANSMITTER (RS485 - Ethernet TCP/IP)
DIGITAL WEIGHT TRANSMITTER (RS485 - Ethernet TCP/IP)
4 independent reading channels for load cells (individual load cell monitoring, total weight displaying, digital equalization).  

  • Ethernet TCP/IP port for remote management (connectable to your PC, smartphone, tablet, etc. via web)
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for front/back panel
TLB4 ETHERCAT - DIGITAL WEIGHT TRANSMITTER (RS485 -  EtherCAT)
DIGITAL WEIGHT TRANSMITTER (RS485 - EtherCAT)
4 independent reading channels for load cells (individual load cell monitoring, total weight displaying, digital equalization).  

  • Two EtherCAT ports
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for front/back panel
TLB4 POWERLINK - DIGITAL WEIGHT TRANSMITTER (RS485 – POWERLINK)
DIGITAL WEIGHT TRANSMITTER (RS485 – POWERLINK)
4 independent reading channels for load cells (individual load cell monitoring, total weight displaying, digital equalization).

  • Two POWERLINK ports
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for front/back panel
TLB4 SERCOS III - DIGITAL WEIGHT TRANSMITTER (RS485 - SERCOS III)
DIGITAL WEIGHT TRANSMITTER (RS485 - SERCOS III)
4 independent reading channels for load cells (individual load cell monitoring, total weight displaying, digital equalization).  

  • Two SERCOS III ports
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for front/back panel
LCB - UNIVERSAL LOAD CELLS DIGITIZER
UNIVERSAL LOAD CELLS DIGITIZER
LCB Digitizer transforms an analog load cell (output mV/V) into digital and can also be used on existing load cells or strain gauge sensors. Designed for an assembly/wiring integral with the load cell body, it can be connected by fieldbus to PLCs of the most important international brands. The weight calculation frequency reaches up to 500 values a second and also the update frequency of the data on the fieldbus can reach the maximum speed of 500 updates a second, when using the PROFINET, EtherNet/IP and EtherCAT buses.
  • Optional fieldbuses: PROFINET IO, Ethernet/IP, Ethernet TCP/IP, Modbus TCP, PROFIBUS DP, EtherCAT, POWERLINK, CANopen, CC-Link, CC-Link IE Field Basic, SERCOS III, IO-LINK.
  • Micro USB port
  • 16-bit Analog output: 0/4-20 mA; 0-5/10 V (optional)
  • RS485 port (optional)
  • Direct connection between RS485 and RS232 without converter.
  • 2 logic inputs, 3 relay outputs
  • Single loading batchings, max 99 formulas
  • Mounting: wired or integral to the load cell body via standard ¼ GAS fitting
  • Suitable for wall mounting
LCB 3A - HYGIENIC UNIVERSAL DIGITIZER FOR LOAD CELLS
HYGIENIC UNIVERSAL DIGITIZER FOR LOAD CELLS

LCB Digitizer transforms an analog load cell (output mV/V) into digital and can also be used on existing load cells or strain gauge sensors. Designed for an assembly/wiring integral with the load cell body, it can be connected by fieldbus to PLCs of the most important international brands. The weight calculation frequency reaches up to 500 values a second and also the update frequency of the data on the fieldbus can reach the maximum speed of 500 updates a second, when using the PROFINET, EtherNet/IP and EtherCAT buses.

  • Hygienic device RPSCQC authorized by 3-A SSI
  • Optional fieldbuses: PROFINET IO, Ethernet/IP, Ethernet TCP/IP, Modbus TCP, PROFIBUS DP, EtherCAT, POWERLINK, CANopen, CC-Link, CC-Link IE Field Basic, SERCOS III, IO-LINK.
  • Micro USB port
  • 16-bit Analog output: 0/4-20 mA; 0-5/10 V (optional)
  • RS485 port (optional)
  • Direct connection between RS485 and RS232 without converter
  • 2 logic inputs, 3 relay outputs
  • Single loading batchings, max 99 formulas
  • Mounting: wired or integral to the load cell body via standard ¼ GAS fitting
TLKWF - WiFi DIGITAL WEIGHT TRANSMITTER (RS232 - RS485)
WiFi DIGITAL WEIGHT TRANSMITTER (RS232 - RS485)
  • Wifi module for wireless connection via integrated web server (for remote management to PC, smartphone, tablet, etc.) or via Modbus RTU/Laumas ASCII protocol.
  • RS232 and RS485 ports (Modbus RTU/Laumas ASCII protocol)
  • Connectable to others TLKWF devices and W series Laumas instruments with OPZW1RADIO optional
  • 2 digital inputs, 4 relay digital outputs
  • 1 load cell input
  • Wall mounting
TLK - DIGITAL WEIGHT TRANSMITTER (RS232 - RS485)
DIGITAL WEIGHT TRANSMITTER (RS232 - RS485)
  • RS232 and RS485 ports (Modbus RTU/Laumas ASCII protocol)
  • 2 digital inputs, 4 relay digital outputs
  • 1 load cell input
  • Wall mounting
MODWF - WiFi/SERIAL TRANSCEIVER (RS232 – RS485)
WiFi/SERIAL TRANSCEIVER (RS232 – RS485)
WiFi communication interface device between two serial devices.

  • Wifi module for wireless connection via Modbus RTU, Laumas ASCII protocol
  • RS232 and RS485 ports (Modbus RTU/Laumas ASCII protocol)
  • Connectable to others MODWF devices devices and W series Laumas instruments with OPZW1RADIO optional
  • Wall mounting
TLB - DIGITAL-ANALOG WEIGHT TRANSMITTER (RS485)
DIGITAL-ANALOG WEIGHT TRANSMITTER (RS485)
  • 16-bit Analog output: 0/4-20 mA; 0-5/10 V; ±5/10 V
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • OIML R61 - WELMEC Guide 8.8:2011 (M.I.D.)
  • Back panel mounting on Omega/DIN rail
TLB 485 - DIGITAL WEIGHT TRANSMITTER (RS485)
DIGITAL WEIGHT TRANSMITTER (RS485)
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • OIML R61 - WELMEC Guide 8.8:2011 (M.I.D.)
  • Back panel mounting on Omega/DIN rail
TLB CANOPEN - DIGITAL WEIGHT TRANSMITTER (RS485 -  CANopen)
DIGITAL WEIGHT TRANSMITTER (RS485 - CANopen)
  • CANopen port
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • OIML R61 - WELMEC Guide 8.8:2011 (M.I.D.)
  • Back panel mounting on Omega/DIN rail
TLB DEVICENET - DIGITAL WEIGHT TRANSMITTER (RS485 -  DeviceNet)
DIGITAL WEIGHT TRANSMITTER (RS485 - DeviceNet)
  • DeviceNet port
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • OIML R61 - WELMEC Guide 8.8:2011 (M.I.D.)
  • Back panel mounting on Omega/DIN rail
TLB CC-LINK - DIGITAL WEIGHT TRANSMITTER (RS485 - CC-Link)
DIGITAL WEIGHT TRANSMITTER (RS485 - CC-Link)
  • CC-Link port
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • OIML R61 - WELMEC Guide 8.8:2011 (M.I.D.)
  • Back panel mounting on Omega/DIN rail
TLB PROFI - DIGITAL WEIGHT TRANSMITTER (RS485 -  PROFIBUS)
DIGITAL WEIGHT TRANSMITTER (RS485 - PROFIBUS)
  • PROFIBUS DP port
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • OIML R61 - WELMEC Guide 8.8:2011 (M.I.D.)
  • Back panel mounting on Omega/DIN rail
TLB PROFINET IO - DIGITAL WEIGHT TRANSMITTER (RS485 - PROFINET IO)
DIGITAL WEIGHT TRANSMITTER (RS485 - PROFINET IO)
  • Two PROFINET IO ports
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • OIML R61 - WELMEC Guide 8.8:2011 (M.I.D.)
  • Back panel mounting on Omega/DIN rail
TLB ETHERNET/IP - DIGITAL WEIGHT TRANSMITTER (RS485 - Ethernet/IP)
DIGITAL WEIGHT TRANSMITTER (RS485 - Ethernet/IP)
  • 2 Ethernet /IP ports
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • OIML R61 - WELMEC Guide 8.8:2011 (M.I.D.)
  • Back panel mounting on Omega/DIN rail
TLB MODBUS/TCP - DIGITAL WEIGHT TRANSMITTER (RS485 - Modbus/TCP)
DIGITAL WEIGHT TRANSMITTER (RS485 - Modbus/TCP)
  • Modbus/TCP port
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • OIML R61 - WELMEC Guide 8.8:2011 (M.I.D.)
  • Back panel mounting on Omega/DIN rail
TLB ETHERNET TCP/IP - DIGITAL WEIGHT TRANSMITTER (RS485 - Ethernet TCP/IP)
DIGITAL WEIGHT TRANSMITTER (RS485 - Ethernet TCP/IP)
  • Ethernet TCP/IP port for remote management (connectable to your PC, smartphone, tablet, etc. via web)
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • OIML R61 - WELMEC Guide 8.8:2011 (M.I.D.)
  • Back panel mounting on Omega/DIN rail
TLB ETHERCAT - DIGITAL WEIGHT TRANSMITTER (RS485 -  EtherCAT)
DIGITAL WEIGHT TRANSMITTER (RS485 - EtherCAT)
  • Two EtherCAT ports
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • OIML R61 - WELMEC Guide 8.8:2011 (M.I.D.)
  • Back panel mounting on Omega/DIN rail
TLB POWERLINK - DIGITAL WEIGHT TRANSMITTER (RS485 – POWERLINK)
DIGITAL WEIGHT TRANSMITTER (RS485 – POWERLINK)
  • Two POWERLINK ports
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • OIML R61 - WELMEC Guide 8.8:2011 (M.I.D.)
  • Back panel mounting on Omega/DIN rail
TLB SERCOS III - DIGITAL WEIGHT TRANSMITTER (RS485 - SERCOS III)
DIGITAL WEIGHT TRANSMITTER (RS485 - SERCOS III)
  • Two SERCOS III ports
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • OIML R61 - WELMEC Guide 8.8:2011 (M.I.D.)
  • Back panel mounting on Omega/DIN rail
CLM8 - INTELLIGENT JUNCTION BOX - 8 CHANNELS FOR LOAD CELLS
INTELLIGENT JUNCTION BOX - 8 CHANNELS FOR LOAD CELLS
The CLM8 series offers the benefits and performance of an advanced digital weighing system even using analog load cells. 8 independent reading channels for load cells. Digital equalization. Automatic diagnostics.

  • Ethernet TCP/IP port for remote management (connectable to your PC, smartphone, tablet, etc. via web)
  • RS232 and RS485 ports (Modbus RTU/Laumas ASCII protocol)
  • OIML R76:2006 approved, class III, 3x5000 divis. 0.4μV/VSI

Available versions:

  • IP67 stainless steel box: 200x148x45 mm; 8+2 cable glands - plugs.
  • IP67 ABS box: 210x130x40 mm; 4/8+3 cable glands - plugs, 4/8+2 PVC end fittings.
  • IP67 polycarbonate box: 170x140x95 mm; 4/8+2 cable glands – plugs, 4+2 PVC end fittings.
  • Omega/DIN rail mounting version: 125x92x52 mm.
  • Board only: 151x72x30 mm.
TLM8 CANOPEN - DIGITAL-ANALOG WEIGHT TRANSMITTER (RS485, CANopen) 8 CHANNELS FOR LOAD CELLS
DIGITAL-ANALOG WEIGHT TRANSMITTER (RS485, CANopen) 8 CHANNELS FOR LOAD CELLS
The TLM8 offers the benefits and performance of an advanced digital weighing system even using analog load cells. 8 independent reading channels for load cells. Digital equalization. Automatic diagnostics.

  • Slave CANopen port, max 99 instruments
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 3 logic inputs, 5 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for back panel or junction box
  • Hygienic version RPSCQC authorized by 3-A SSI
TLM8 DEVICENET - DIGITAL-ANALOG WEIGHT TRANSMITTER (RS485, DeviceNet) 8 CHANNELS FOR LOAD CELLS
DIGITAL-ANALOG WEIGHT TRANSMITTER (RS485, DeviceNet) 8 CHANNELS FOR LOAD CELLS
The TLM8 offers the benefits and performance of an advanced digital weighing system even using analog load cells. 8 independent reading channels for load cells. Digital equalization. Automatic diagnostics.

  • Slave DeviceNet port, max 64 instruments
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 3 logic inputs, 5 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for back panel or junction box
  • Hygienic version RPSCQC authorized by 3-A SSI
TLM8 CC-LINK - DIGITAL-ANALOG WEIGHT TRANSMITTER (RS485, CC-Link) 8 CHANNELS FOR LOAD CELLS
DIGITAL-ANALOG WEIGHT TRANSMITTER (RS485, CC-Link) 8 CHANNELS FOR LOAD CELLS
The TLM8 offers the benefits and performance of an advanced digital weighing system even using analog load cells. 8 independent reading channels for load cells. Digital equalization. Automatic diagnostics.

  • Slave CC-Link port, max 64 instruments
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 3 logic inputs, 5 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for back panel or junction box
  • Hygienic version RPSCQC authorized by 3-A SSI
TLM8 PROFIBUS - DIGITAL-ANALOG WEIGHT TRANSMITTER (RS485, PROFIBUS) 8 CHANNELS FOR LOAD CELLS
DIGITAL-ANALOG WEIGHT TRANSMITTER (RS485, PROFIBUS) 8 CHANNELS FOR LOAD CELLS
The TLM8 offers the benefits and performance of an advanced digital weighing system even using analog load cells. 8 independent reading channels for load cells. Digital equalization. Automatic diagnostics.

  • Slave PROFIBUS DP port (max 32 instruments without line repeaters; max 126 instruments with line repeaters)
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 3 logic inputs, 5 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for back panel or junction box
  • Hygienic version RPSCQC authorized by 3-A SSI
TLM8 PROFINET IO - DIGITAL-ANALOG WEIGHT TRANSMITTER (RS485, PROFINET IO) 8 CHANNELS FOR LOAD CELLS
DIGITAL-ANALOG WEIGHT TRANSMITTER (RS485, PROFINET IO) 8 CHANNELS FOR LOAD CELLS
The TLM8 offers the benefits and performance of an advanced digital weighing system even using analog load cells. 8 independent reading channels for load cells. Digital equalization. Automatic diagnostics.  

  • Two PROFINET IO ports
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 3 logic inputs, 5 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for back panel or junction box
  • Hygienic version RPSCQC authorized by 3-A SSI
TLM8 ETHERNET/IP - DIGITAL-ANALOG WEIGHT TRANSMITTER (RS485, Ethernet/IP) 8 CHANNELS FOR LOAD CELLS
DIGITAL-ANALOG WEIGHT TRANSMITTER (RS485, Ethernet/IP) 8 CHANNELS FOR LOAD CELLS
The TLM8 offers the benefits and performance of an advanced digital weighing system even using analog load cells. 8 independent reading channels for load cells. Digital equalization. Automatic diagnostics.

  • Slave Ethernet /IP port
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 3 logic inputs, 5 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for back panel or junction box
  • Hygienic version RPSCQC authorized by 3-A SSI
TLM8 MODBUS/TCP - DIGITAL-ANALOG WEIGHT TRANSMITTER (RS485, Modbus/TCP) 8 CHANNELS FOR LOAD CELLS
DIGITAL-ANALOG WEIGHT TRANSMITTER (RS485, Modbus/TCP) 8 CHANNELS FOR LOAD CELLS
The TLM8 offers the benefits and performance of an advanced digital weighing system even using analog load cells. 8 independent reading channels for load cells. Digital equalization. Automatic diagnostics.  

  • Slave Modbus/TCP port
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 3 logic inputs, 5 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for back panel or junction box
  • Hygienic version RPSCQC authorized by 3-A SSI
TLM8 ETHERCAT - DIGITAL-ANALOG WEIGHT TRANSMITTER (RS485, EtherCAT) 8 CHANNELS FOR LOAD CELLS
DIGITAL-ANALOG WEIGHT TRANSMITTER (RS485, EtherCAT) 8 CHANNELS FOR LOAD CELLS
The TLM8 offers the benefits and performance of an advanced digital weighing system even using analog load cells. 8 independent reading channels for load cells. Digital equalization. Automatic diagnostics.  

  • Two EtherCAT ports
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 3 logic inputs, 5 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for back panel or junction box
  • Hygienic version RPSCQC authorized by 3-A SSI
TLM8 ETHERNET TCP/IP - DIGITAL-ANALOG WEIGHT TRANSMITTER (RS485, Ethernet TCP/IP) 8 CHANNELS FOR LOAD CELLS
DIGITAL-ANALOG WEIGHT TRANSMITTER (RS485, Ethernet TCP/IP) 8 CHANNELS FOR LOAD CELLS
The TLM8 offers the benefits and performance of an advanced digital weighing system even using analog load cells. 8 independent reading channels for load cells. Digital equalization. Automatic diagnostics.
 
  • Ethernet TCP/IP port for remote management (connectable to your PC, smartphone, tablet, etc. via web)
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 3 logic inputs, 5 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for back panel or junction box
  • Hygienic version RPSCQC authorized by 3-A SSI
TLM8 POWERLINK - DIGITAL-ANALOG WEIGHT TRANSMITTER (RS485, POWERLINK) 8 CHANNELS FOR LOAD CELLS
DIGITAL-ANALOG WEIGHT TRANSMITTER (RS485, POWERLINK) 8 CHANNELS FOR LOAD CELLS
The TLM8 offers the benefits and performance of an advanced digital weighing system even using analog load cells. 8 independent reading channels for load cells. Digital equalization. Automatic diagnostics.  

  • Two POWERLINK ports
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 3 logic inputs, 5 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for back panel or junction box
  • Hygienic version RPSCQC authorized by 3-A SSI
TLM8 SERCOS III - DIGITAL-ANALOG WEIGHT TRANSMITTER (RS485, SERCOS III) 8 CHANNELS FOR LOAD CELLS
DIGITAL-ANALOG WEIGHT TRANSMITTER (RS485, SERCOS III) 8 CHANNELS FOR LOAD CELLS
The TLM8 offers the benefits and performance of an advanced digital weighing system even using analog load cells. 8 independent reading channels for load cells. Digital equalization. Automatic diagnostics.  

  • Two SERCOS III ports
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 3 logic inputs, 5 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for back panel or junction box
  • Hygienic version RPSCQC authorized by 3-A SSI
TLM8 - DIGITAL-ANALOG WEIGHT TRANSMITTER (RS485) 8 CHANNELS FOR LOAD CELLS
DIGITAL-ANALOG WEIGHT TRANSMITTER (RS485) 8 CHANNELS FOR LOAD CELLS
The TLM8 offers the benefits and performance of an advanced digital weighing system even using analog load cells. 8 independent reading channels for load cells. Digital equalization. Automatic diagnostics.

  • 16-bit Analog output: 0/4-20 mA; 0-5/10 V
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 3 logic inputs, 5 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for back panel or junction box
  • Hygienic version RPSCQC authorized by 3-A SSI
CASTLM8I - KASTEN AUS EDELSTAHL FÜR WÄGETRANSMITTER TLM8
KASTEN AUS EDELSTAHL FÜR WÄGETRANSMITTER TLM8
Für mehrkanaligen Wägetransmitter TLM8.

  • Schutzart IP68 (auf Anfrage IP69K)
  • Einbau an: Schalttafelfront, Wand, Tisch
  • Version ATEX II 3GD
  • TEST-Taste für den direkten Zugriff auf Diagnosefunktionen
CASTLM8I 3A - HYGIENIC STAINLESS STEEL BOX FOR TLM8 TRANSMITTER
HYGIENIC STAINLESS STEEL BOX FOR TLM8 TRANSMITTER

For multichannel weight transmitter series TLM8.

  • Hygienic device RPSCQC authorized by 3-A SSI
  • IP69K protection rating
  • Panel mounting
  • TEST key for direct access to the diagnostic functions
TLE - ANALOG WEIGHT TRANSMITTER (RS485)
ANALOG WEIGHT TRANSMITTER (RS485)
  • 16-bit Analog output: 0/4-20 mA; 0-5/10 V; ±5/10 V
  • RS485 port (Modbus RTU)
  • Simple zero setting and full scale through digital rotary control (Encoder)
  • Mounting on Omega/DIN rail for back panel or junction box
  • Box versions: IP67, IP67 ATEX II 3GD
TLS 485 - DIGITAL WEIGHT TRANSMITTER (RS485)
DIGITAL WEIGHT TRANSMITTER (RS485)
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 2 optorelays logic outputs
  • Mounting on Omega/DIN rail for back panel or junction box
  • Box versions: IP67, IP67 ATEX II 3GD
WEBLAU - WEB SERVER MASTER FOR W AND TLB SERIES (max 8)
WEB SERVER MASTER FOR W AND TLB SERIES (max 8)
  • Ideal for supervision, management and remote control of the W series weight indicators and TLB series weight transmitters (max 8 instruments)
  • RS485 port (Modbus RTU)
  • Ethernet TCP/IP port for remote management via internet from PC, smartphone or tablet, etc.
  • Back panel mounting on Omega/DIN rail  

The WEBLAU device is a useful support for all installers/dealers of Laumas weighing instruments as it makes easier the remote maintenance, allowing to control wherever, the status of the instruments connected to RS485 including the possible anomalies.
TLS - DIGITAL-ANALOG WEIGHT TRANSMITTER (RS485)
DIGITAL-ANALOG WEIGHT TRANSMITTER (RS485)
  • 16-bit Analog output: 0/4-20 mA; 0-5/10 V; ±5/10 V
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 2 optorelays logic outputs
  • Mounting on Omega/DIN rail for back panel or junction box
  • Box versions: IP67, IP67 ATEX II 3GD
THFPROFI - DIGITAL WEIGHT TRANSMITTER (RS485 -  PROFIBUS)
DIGITAL WEIGHT TRANSMITTER (RS485 - PROFIBUS)
  • Slave Profibus DP port (max 32 instruments without line repeaters; max 126 instruments with line repeaters)
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 1 logic input, 1 relay output
  • Mounting on Omega/DIN rail for back panel or junction box
  • Box versions: IP67, IP67 ATEX II 3GD
TLU - DIGITAL-ANALOG LOAD LIMITING DEVICE/INDICATOR
DIGITAL-ANALOG LOAD LIMITING DEVICE/INDICATOR
  • 16-bit Analog output: 0/4-20 mA; 0-5/10 V; ±5/10 V (optional)
  • RS232 and RS485 ports (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 4 relay outputs
  • Mounting on Omega/DIN rail for back panel or junction box
  • Box versions: IP67, IP67 ATEX II 3GD
TLL - DIGITAL WEIGHT TRANSMITTER (RS232 - RS485)
DIGITAL WEIGHT TRANSMITTER (RS232 - RS485)
  • Synchronous weight transmission for PLCs without serial port
  • 16-bit Analog output: 0/4-20 mA; 0-5/10 V; ±5/10 V (optional)
  • RS232 and RS485 ports (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 4 relay outputs
  • Mounting on Omega/DIN rail for back panel or junction box
  • Box versions: IP67, IP67 ATEX II 3GD
CASTLATEX - IP67 CASE WITH TRANSPARENT COVER
IP67 CASE WITH TRANSPARENT COVER
For weight transmitter series TLE

  • ATEX II 3GD approved
  • Dimensions 170x140x95 mm; centre distance 122x152 mm
  • 6 M16x1.5 cable glands
CASTLTASTATEX - IP67 CASE WITH EXTERNAL KEYPAD
IP67 CASE WITH EXTERNAL KEYPAD
For weight transmitters: TLS, TLS485, TLU, TLL, THFPROFI

  • ATEX II 3GD approved
  • Dimensions 170x140x95 mm; centre distance 122x152 mm
  • 6 M16x1.5 cable glands
LCD3 - DIGITAL LOAD LIMITING DEVICE
DIGITAL LOAD LIMITING DEVICE
  • Suitable for lifting systems
  • Single/multi-weighing system: load limitation (single and sum) for systems with up to 4 weighing points, by connecting multiple units.
  • 3 relay outputs
  • 1 load cell dedicated input
  • Load cells connections continuous check
  • Mounting on Omega/DIN rail for back panel or junction box
  • RS232 and RS485 ports
  • 2 digital inputs
  • Power Supply 24-48 Vdc/Vac
LCD3PL - DIGITAL LOAD LIMITING DEVICE
DIGITAL LOAD LIMITING DEVICE
  • Suitable for lifting systems
  • Dual channel input system for single or double bridge load cells, in accordance with category 2 as per EN 13849-1:2008, PL d (corresponding to SIL 2, EN62061 standard).
  • 4 relay outputs
  • 2 independent load cell inputs
  • Load cells connections continuous check
  • Mounting on Omega/DIN rail for back panel or junction box
  • RS232 and RS485 ports
  • 2 digital inputs
  • Power Supply 24-48 Vdc/Vac