INNOVATION IN WEIGHING

Соединительные коробки и кабели

ВЫ ИЩИТЕ ИЗДЕЛИЕ?

Поиск по подлинейка продукции
Искать по модели продукта
Показать поисковые фильтры
CDG 3A - HYGIENIC BOX WITH 1-4 CELLS EQUALIZATION / PARALLEL BOARD
HYGIENIC BOX WITH 1-4 CELLS EQUALIZATION / PARALLEL BOARD

Hygienic junction box in AISI 304 stainless steel:

  • 1-4 cells equalization board (4/6 wires)
  • 1-4 cells parallel board (4/6 wires)
Certified 3-A Sanitary Standards.
CLM8 - INTELLIGENT JUNCTION BOX - 8 CHANNELS FOR LOAD CELLS
INTELLIGENT JUNCTION BOX - 8 CHANNELS FOR LOAD CELLS
The CLM8 series offers the benefits and performance of an advanced digital weighing system even using analog load cells. 8 independent reading channels for load cells. Digital equalization. Automatic diagnostics.

  • Ethernet TCP/IP port for remote management (connectable to your PC, smartphone, tablet, etc. via web)
  • RS232 and RS485 ports (Modbus RTU/Laumas ASCII protocol)
  • OIML R76:2006 approved, class III, 3x5000 divis. 0.4μV/VSI

Available versions:

  • IP67 stainless steel box: 200x148x45 mm; 8+2 cable glands - plugs.
  • IP67 ABS box: 210x130x40 mm; 4/8+3 cable glands - plugs, 4/8+2 PVC end fittings.
  • IP67 polycarbonate box: 170x140x95 mm; 4/8+2 cable glands – plugs, 4+2 PVC end fittings.
  • Omega/DIN rail mounting version: 125x92x52 mm.
  • Board only: 151x72x30 mm.
HL6N - BOARD TO CONNECT UP TO 4 LOAD CELLS IN PARALLEL
BOARD TO CONNECT UP TO 4 LOAD CELLS IN PARALLEL
Board to connect up to 4 load cells in parallel (4/6 wires).
HL6EQSN - EQUALIZATION BOARD TO CONNECT UP TO 4 LOAD CELLS
EQUALIZATION BOARD TO CONNECT UP TO 4 LOAD CELLS
Sensitivity equalization board to connect up to 4 load cells in parallel (with difference in sensitivity less than or equal to 0.1 mV/V for 2 mV/V load cells).
C41INOXP - UP TO 4 CELLS PARALLEL BOARD MOUNTED INSIDE SST CASE
UP TO 4 CELLS PARALLEL BOARD MOUNTED INSIDE SST CASE
  • 4 + 1 cable glands-plugs
  • IP67 protection rating
  • Dimensions 176 x 90 x 42 mm; centre distance 20 x 160 mm
CE41INOXP - UP TO 4 CELLS EQUALIZATION BOARD MOUNTED INSIDE SST CASE
UP TO 4 CELLS EQUALIZATION BOARD MOUNTED INSIDE SST CASE
  • 4 + 1 cable glands-plugs
  • IP67 protection rating
  • Dimensions 176 x 90 x 42 mm; centre distance 20 x 160 mm
CE41INOX - UP TO 4 CELLS EQUALIZATION BOARD MOUNTED INSIDE SST CASE
UP TO 4 CELLS EQUALIZATION BOARD MOUNTED INSIDE SST CASE
  • 4 + 1 cable glands-plugs
  • IP67 protection rating
  • Dimensions 143 x 142 x 42 mm; centre distance 112 x 128 mm
  • Earth terminal
  • Lightning and electrical shock protection device
CE81INOX - UP TO 8 CELLS EQUALIZATION BOARD MOUNTED INSIDE SST CASE
UP TO 8 CELLS EQUALIZATION BOARD MOUNTED INSIDE SST CASE
  • 8 + 1 cable glands-plugs
  • IP67 protection rating
  • Dimensions 200 x 149 x 43 mm; centre distance 147 x 135 mm
  • Earth terminal
  • Lightning and electrical shock protection device
CE41ATEX - UP TO 4 CELLS EQUALIZATION BOARD MOUNTED INSIDE SST CASE
UP TO 4 CELLS EQUALIZATION BOARD MOUNTED INSIDE SST CASE
  • ATEX II 1GD approved
  • 4 + 1 cable glands-plugs
  • IP67 protection rating
  • Dimensions 144 x 142 x 42 mm; centre distance 112 x 128 mm
  • Earth terminal
CE81ATEX - UP TO 8 CELLS EQUALIZATION BOARD MOUNTED INSIDE SST CASE
UP TO 8 CELLS EQUALIZATION BOARD MOUNTED INSIDE SST CASE
  • ATEX II 1GD approved
  • 8 + 1 cable glands-plugs
  • IP67 protection rating
  • Dimensions 200 x 149 x 43 mm; centre distance 147 x 135 mm
  • Earth terminal
CE41PATEX - UP TO 4 CELLS EQUALIZATION BOARD MOUNTED INSIDE SST CASE
UP TO 4 CELLS EQUALIZATION BOARD MOUNTED INSIDE SST CASE
  • ATEX II 1GD approved
  • 4 + 1 cable glands-plugs
  • IP67 protection rating
  • Dimensions 176 x 90 x 42 mm; centre distance 20 x 160 mm
CIP67N - UP TO 4 CELLS PARALLEL BOARD MOUNTED INSIDE ABS CASE
UP TO 4 CELLS PARALLEL BOARD MOUNTED INSIDE ABS CASE
  • IP67 protection rating
  • Dimensions 180 x 130 x 35 mm; centre distance 163 x 113 mm
C41N - UP TO 4 CELLS PARALLEL BOARD MOUNTED INSIDE ABS CASE
UP TO 4 CELLS PARALLEL BOARD MOUNTED INSIDE ABS CASE
  • 4 + 1 cable glands - plugs
  • IP67 protection rating
  • Dimensions 180 x 130 x 35 mm; centre distance 163 x 113 mm
C41NR - UP TO 4 CELLS PARALLEL BOARD MOUNTED INSIDE ABS CASE
UP TO 4 CELLS PARALLEL BOARD MOUNTED INSIDE ABS CASE
  • 4 + 1 PVC fittings for sheath
  • IP67 protection rating
  • Dimensions 180 x 130 x 35 mm; centre distance 163 x 113 mm
CE41N - UP TO 4 CELLS EQUALIZATION BOARD MOUNTED INSIDE ABS CASE
UP TO 4 CELLS EQUALIZATION BOARD MOUNTED INSIDE ABS CASE
  • 4 + 1 cable glands - plugs
  • IP67 protection rating
  • Dimensions 180 x 130 x 35 mm; centre distance 163 x 113 mm
CE41NR - UP TO 4 CELLS EQUALIZATION BOARD MOUNTED INSIDE ABS CASE
UP TO 4 CELLS EQUALIZATION BOARD MOUNTED INSIDE ABS CASE
  • 4 + 1 PVC fittings for sheath
  • IP67 protection rating
  • Dimensions 180 x 130 x 35 mm; centre distance 163 x 113 mm
CE81PN - UP TO 8 CELLS EQUALIZATION BOARD MOUNTED INSIDE ABS CASE
UP TO 8 CELLS EQUALIZATION BOARD MOUNTED INSIDE ABS CASE
  • 8 + 2 cable glands - plugs
  • IP67 protection rating
  • Dimensions 180 x 130 x 35 mm; centre distance 163 x 113 mm
  • Earth terminal
  • Lightning and electrical shock protection device
CE81PNR - UP TO 8 CELLS EQUALIZATION BOARD MOUNTED INSIDE ABS CASE
UP TO 8 CELLS EQUALIZATION BOARD MOUNTED INSIDE ABS CASE
  • 8 + 2 PVC fittings for sheath
  • IP67 protection rating
  • Dimensions 180 x 130 x 35 mm; centre distance 163 x 113 mm
  • Earth terminal
  • Lightning and electrical shock protection device
CAVO6020S - SHIELDED CABLE
SHIELDED CABLE
Shielded cable 6 x 0.22 mm2.
Available coil of cable: 5 - 10 - 200 m.
CAVO6020SARM - ANTI RAT SHIELDED CABLE
ANTI RAT SHIELDED CABLE
Anti rat shielded cable 6 x 0.22 mm2.
Available coil of cable: 5 - 10 - 200 m.
GUA - PVC SHEATH
PVC SHEATH
PVC Flexible Sheath IP67 (Ø 10 x 14 mm) to cover the cables of the load cells (only for load cells with threaded cable glands).
ESTENSIONE - EXTENSION PVC-SHEATHED CABLE
EXTENSION PVC-SHEATHED CABLE
Extension PVC-sheathed IP67 cable 6 x 0.22 mm2.
EC - COMMUTATOR FOR FORMULAS/SETPOINT SELECTION
COMMUTATOR FOR FORMULAS/SETPOINT SELECTION
EC:12 formulas/setpoint selection from external commutator

EC2
:2x12 formulas/setpoint selection from commutator (for 2 instruments)

EC3
:3x12 formulas/setpoint selection from commutator (for 3 instruments)
E - OPTION FOR 12 GROUPS SELECTION BY 5 SETPOINT
OPTION FOR 12 GROUPS SELECTION BY 5 SETPOINT
12 groups selection by 5 setpoint via external contact.